Batch #4 (STEP1)
 
Analysis Summary Statistics Summary


  • 480 nm quantum efficiency


The table (1) gives the mean value for each sub-batch, without any intercalibration. Only the PMTs, which fulfil the specifications, have been used in the calculations.


Sub-Batches

QE mean value (%)

Sub-Batch 4-1 (250 PM)

18,8

Sub-Batch 4-2 (250 PM)

19,3

Sub-Batch 4-3 (250 PM)

19,2

Sub-Batch 4-4 (250 PM)

19,1

Sub-Batch 4-5 (250 PM)

19,2

Full Batch

19,1

Table 1 : Quantum Efficiency mean value (%)



The distribution of the 480 nm efficiency is reported on figure (1. The rejected PMTs (all) are quoted in red. This criterion is ok: the mean value for each sub-batch is above 18.0% as indicated in the table (1) and no tube has a value lower than 15%.


 Next
Batch #4
1250 PMTS
(5 sub-batches)
tested by
  1. Valencia
    (250 PMTS)
  2. Pisa
    (250 PMTS)
  3. Urbana
    (2*250 PMTS)
  4. Clermont Ferrand
    (250 PMTS)